Hacemey Pet clinic and hospital Emergency Anesthesia Equipment Medical Gas vet anaesthesia machine Veterinary Use

Hacemey Vet Pet Anesthesia machine with Smart ventilator

Share:

  • Smart 9-inch touch screen; integrated anesthesia machine with ventilator, saving labor costs
  • Respiration modes include PCV,VCV,SPONT,DEMO.Just set the weight, other parameters are automatically calculated
  • With Electric PEEP function
  • Animal-specific bellows design to meet the needs of clinical scientific research.
  • The internal battery can be used for more than two hours.
  • Suitable for small animals, Non-breathing circuit(Jackson or Bains Absorber) is available.
  • Selectatec-bar and quick change vaporizer mounting device.
  • Professional airtight breathing circuit design, provide the stable gas anesthesia, save anesthesia gas consumption,
  • to ensure a clean operating room and laboratory environment.
  • External and reusable soda lime canister, easily watch and replace soda lime.
  • With Oxygen flush function to ensure that clinical anesthesia demand and Oxygen supply demand.
  • Anaesthesia CO2 absorber assembly has no dead angle design, fast anesthesia, short recovery and high precision.
  • The CO2 absorber supports both open loop and closed loop anaesthesia design and provides independent access .
  • Provide a special Pop-Off valve,Occlusion design, it can connected to the exhaust gas recovery system and provide a continuous 2 cmH2O negative pressure for the reaspirato airbag ,reducing valve to prevent pressure to hurt the animal, ensure the animal safety .
  • Provides an accurate oxygen flow meter with a display range of 0 to 5LPM
  • Vaporizer: the output concentration is not affected by the change of flow, pressure and temperature, accurate and reliable,
  • equipped with safety locking device to prevent anesthetic leakage. Isoflurane,sevoflurane and halothane vaporizer are optional.
  • The hard aluminum solid shell is used, and the surface sanding treatment is adopted, so that the cleaning and disinfection are more convenient.
  • Visible inspiration and expiration valve
  • With fresh gas output connector ,specifically designed to accomodate low flow
  • Specifications:
  • Hacemey Vet Anesthesia and ventilator HIA-V2
    Respiration mode PCV,VCV,SPONT,DEMO
    Bellow Big animal t:50-1600ml,small animal:0-300ml
    Screen 9 inches touch screen
    Waveform Pressure,Flow,Volume
    Loop PV,PF,FV
    Tidal volume Mechanical control:20-1600ml
    Manual control:5-1600ml
    BPM 1-100bpm
    I:E 9.9:1to1:9.9
    Inspiratory time 0.1s-10.0s
    Apnea 0-50%
    PEEP Off,3-20cmH2O
    Pressure support 5-60cmH2O
    Flow trigger 0.5-20L/min
    Pressure trigger -1~20cmH2O
    PSV Inspiratory terminal level 25%
    Monitoring Tidal volume,breathing rate,Spontaneous breathing rate,I:E,Spontaneous minute ventilation volume,Minute ventilation peak airway pressure,Average airway pressure,PEEP,Inspiratory platform pressure,FIO2
    Alarm parameters Tidal volume,Minute ventilation volume,Frequency,Airway pressure ,Continuous airway pressure,Negative pressure alarm,Apnea alarm,Air supply pressure failure alarm,Power supply alarm,Low battery alarm,Battery exhaustion alarm,Oxygen battery failure alarm,FIO2(optional),FICO2(optional)
    Power supply 220V±10%,50HZ±1%
  • Vet Main unit
    Ventilation mode Open,Closed,half-closed,half-open
    Drive mode pneumatic
    Application 0.5-100kg animal
    Anesthesia Vaporizer Isoflurane,Sevoflurane,Halothane
    Oxygen Flush 25L/min~75L/min
    Gas source pressure Oxygen 0.25Mpa~0.65Mpa
    Trolley High-quality aluminum alloy profile, with storage frame and special interface for exhaust gas emission
    Flowmeter Oxygen flow meter for animals,

    Scale range:0~5L/min

 

veterinary anesthesia machine

vet anesthesia machine manufacturer

Send a message

Inquiry Hacemey Pet clinic and hospital Emergency Anesthesia Equipment Medical Gas vet anaesthesia machine Veterinary Use